Description
Untitled DocumentLeviton MO240-1SW Mini Meter Kit Outdoor Surface Mount Mechanical Counter 120/208/240V 1P/3W 100A with 2 Solid Core CTs
Model:
MO240-1SW
| Order No:
MO240-1SW
The Leviton MO240-1SW mini meter kit outdoor surface mount meets all measurement and verification based opportunities - including load management and LEED rating achievement. It's designed to provide a simple and effective process for accurately capturing measurements of power consumption, and is easy to specify and install for new construction and retrofits.
Brand:
Leviton
Model:
MO240-1SW
Order No:
MO240-1SW
Condition:
NEW
Description
Leviton MO240-1SW Mini Meter Kit Outdoor Surface Mount Mechanical Counter 120/208/240V 1P/3W 100A with 2 Solid Core CTs
Features
Measures kWh
Revenue-Grade: Conforms to all applicable standards of ANSI C12.1
Equipped standard with an Isolated Pulse Output channel for automated meter reading
Available in indoor flush mount enclosure
Available in NEMA 4X indoor/outdoor enclosure packages and Multiple Meter Units (MMUs) from 2-19 meters
Utilizes revenue-grade 0.3% accuracy class 0.1A secondary solid core current transformers (CTs) that conform to all applicable ANSI requirements or 1.0% accuracy split-core CTs
Up to three sets of CTs per phase can be paralleled per meter without the need for a meter multiplier
CT lead length maximum: 48"
"6" models UL/cUL Listed Energy Usage Monitor per CCN FTRZ; "7" models UL/cUL Recognized Energy Usage Monitoring Equipment
Ten year warranty
Applications
Use Mini Meters in multi-tenant residential and certain commercial industrial applications for:
Load profiling and benchmarking
AMR/BAS/BMS/EMS integration
Usage aggregation
Tenant cost allocation
Measurement and verification
Energy conservation and cost reduction
Green building initiatives and Government mandates
Included
Leviton MO240-1SW Mini Meter Kit Outdoor Surface Mount Mechanical Counter 120/208/240V 1P/3W 100A with 2 Solid Core CTs
Specifications
Electrical
Input Configurations
1 Phase, 2 Wire
1 or 2 Phase, 3 Wire
Supply Voltage Range (L1 or L2 to Neutral)
102 VAC to 138 VAC
Maximum Input Power (L1 and L2)
8 VA
Maximum Rated Current
440 A primary for 400 A models
220 A primary for 200 A models
110 A primary for 100 A models
0.11 A secondary for 0.1 A secondary models
0.22 A secondary for 0.2 A secondary models
Line Frequency
50 to 60 Hz
Power Factor Range
0.5 to 1.0, Leading or Lagging
Accuracy
+/- 0.5% of registration @ 1.0pf. 2 to 200 A
+/- 0.75% of registration @ 0.5pf, 2 to 200 A
Operating Temperature Range
-30 to 60°C
Rated Pollution Degree
2
Rated Relative Humidity
80%
Inputs
Voltage Inputs (Wire Connections)
L1: Black wire, voltage input, Line 1, 120V with respect to neutral
N: White wire, Neutral input
L2: Red wire, voltage input, Line 2, 120V with respect to neutral (7B and 5B models only)
CT Inputs
CT1: X1 Current Transformer input, CT1. Colored wire of CT 1
CT1: X2 Current Transformer input, CT1. White wire of CT1
CT2: X1 Current Transformer input, CT2.Colored wire of CT2 (7B and 5B models only)
CT2: X2 Current Transformer input, CT2. White wire of CT2 (7B and 5B models only)
Outputs
10, Isolated Output (10 Wh/P, Kh = 10)
Isolated Pulse Output: 5 watthours on, 5 watthours off, referenced to ISOL COM NOT TO BE USED FOR FIELD WIRING
100, Isolated Output (100 Wh/P, Kh=100)
Isolated Pulse Output: 50 watthours on, 50 watthours off, referenced to ISOL COM
1000, Isolated Output (1 kWh/P, Kh=1000)
Isolated pulse output: 500 watthours on, 500 watthours off, referenced to ISOL COM (not available on models with T suffix)
ISOL COM
Isolated common for 10/100/1000 isolated outputs
Counter (kh = 100 or kh = 1000)
For 12 VDC electro-mechanical counter
Counter (kh = 100 or kh = 1000)
For 12 VDC electro-mechanical counter
+12 VDC (MMS and MMD models only)
12 VDC Output; current rating is 3 mA max.
LED Indicators
Power LED (Green)
Illuminates when the meter is supplied with proper voltage
Load LED (Green)
50% duty cycle (at constant load) LED to verify proper meter function when connected to a load. At 200 watts, LED will illuminate for 1.5 minutes, then turn off for 1.5 minutes; with no load, LED will remain on or off
Reverse Phase LED (Red)
Illuminates when a problem with meter phasing exists. With no load, LED may be on or off. See CT installation section for instructions.
LCD Display
Optional LCD display that shows total kWh
Terms & Conditions
Item Condition:
Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
Shipping:
We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
*Shipping Rates are for Continental US, Please Contact us for other US Destinations
Payment:
Currently all payments must be made directly though PayPal
Sales Tax:
We are required to charge sales tax in North Carolina
Return Policy:
If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.